The ESI data ingested by github.com/linuxcnc-ethercat/esi-data describes 1 revision(s) of this hardware. Here are the known revisions and their differences.
This also includes the send and receive PDOs defined for each revision, and a link to other known devices with identical PDOs.
| Revision | r16  | 
|
| Name | EJ6224-0090 (IO Link Master, TwinSAFE SC)  | 
|
| PID | 0x18502852  | 
|
| Revision Code | 0x0010005a  | 
|
| Equivalant Devices | ||
| TX PDOs | 0x1a80: DeviceState Inputs  | 
|
0x1a81: DeviceState Inputs  | 
||
0x1a00: IO Inputs Channel 1  | 
||
0x1a01: IO Inputs Channel 2  | 
||
0x1a02: IO Inputs Channel 3  | 
||
0x1a03: IO Inputs Channel 4  | 
||
0x1a90: TSC Inputs  | 
||
0x600f:01 TSC__Slave Cmd USINT (8 bits)  | 
||
0x6004:01 TSC__Value_ch1 UINT (16 bits)  | 
||
0x600f:03 TSC__Slave CRC_0 UINT (16 bits)  | 
||
0x600f:04 TSC__Slave CRC_1 UINT (16 bits)  | 
||
0x600f:05 TSC__Slave CRC_2 UINT (16 bits)  | 
||
0x600f:06 TSC__Slave CRC_3 UINT (16 bits)  | 
||
0x600f:07 TSC__Slave CRC_4 UINT (16 bits)  | 
||
0x600f:08 TSC__Slave CRC_5 UINT (16 bits)  | 
||
0x600f:09 TSC__Slave CRC_6 UINT (16 bits)  | 
||
0x600f:0a TSC__Slave CRC_7 UINT (16 bits)  | 
||
0x600f:02 TSC__Slave ConnID UINT (16 bits)  | 
||
| RX PDOs | 0x1600: IO Outputs Channel 1  | 
|
0x1601: IO Outputs Channel 2  | 
||
0x1602: IO Outputs Channel 3  | 
||
0x1603: IO Outputs Channel 4  | 
||
0x1690: TSC Outputs  | 
||
0x700f:01 TSC__Master Cmd USINT (8 bits)  | 
||
0x700f:03 TSC__Master CRC_0 UINT (16 bits)  | 
||
0x700f:02 TSC__Master ConnID UINT (16 bits)  |